High-frequency twisted-pair LAN cable U/UTP Cat 5e PVC ng(A)-LS

Manufacturing and sale of twisted pair cables U/UTP Cat 5e PVC ng(A)-LS. LAN cable delivery to all regions of Russia.

In stock: many

Delivery: from 1 business day

  • Flame-retardant cable for Category A group installation
  • With reduced smoke and gas emission
  • Unshielded
  • With a polymer compound outer jacket
  • Outer jacket color: gray (upon customer request, the cable can be manufactured with any jacket color).
  • Technical Specifications TU FKS-003-2018
Application area of U/UTP Cat 5e PVC ng(A)-LS:

High-frequency twisted-pair cables for structured cabling systems are intended for fixed horizontal and vertical installation in buildings and structures, taking into account the cable fire load. The cables do not propagate flame during group installation according to Category A and have reduced smoke and gas emission in accordance with GOST 31565-2012. They are designed for operation in a frequency range of up to 100 MHz (Category 5 and 5e according to GOST R 54429-2011 and ISO/IEC 11801). The cables are manufactured in climatic version U, installation categories 3 and 4 according to GOST 15150.

Technical specification:

Name

Number of pairs and conductor diameter, mm

Conductor diameter

Nominal outer cable diameter with conductor Ø 0.50 mm, mm

Cable weight with conductor Ø 0.50 mm,

kg/km

Manufacturing length, km

U/UTP-5e PVC ng(A)-LS

1x2

0.46±0.01

0.48±0.01

0.50±0.01

0.51±0.01

0.52±0.01

3.1

9.05

0.305; 0.5; 1

2x2

5.2

18.53

0.305; 0.5

4x2

5.98

29.44

0.305

8x2

8.08

51.41

0.305

10x2

9.2

62.39

0.305

16x2

11.16

105.06

0.305

25x2

15.12

158.93

0.305

50x2

19.76

290.79

0.305

100x2

25.3

571.25

0.305

 

Electrical characteristics:
  • Conductor resistance recalculated for 100 m cable length at 20°C — not more than 9.6 Ω;
  • DC resistance unbalance of conductors in a working pair over 100 m length — not more than 2%.
  • Attenuation coefficient recalculated for 100 m length and temperature of 20°C, dB, not more than

Frequency, MHz

1

4

10

16

20

31.25

62.5

100

Attenuation, dB

2.1

4.1

6.5

8.3

9.3

11.7

17.0

22.0

 

  • Near-End Crosstalk (NEXT) for any pair combination recalculated for 100 m length, dB, not less than

Frequency, MHz

1

4

10

16

20

31.25

62.5

100

Attenuation, dB

65.3

56.3

50.3

47.3

45.8

42.9

38.4

35.3

 

  • Equal Level Far-End Crosstalk (ELFEXT) for any pair combination recalculated for 100 m length, dB, not less than

Frequency, MHz

1

4

10

16

20

31.25

62.5

100

Attenuation, dB

64.0

52.0

44.0

39.9

38.0

34.1

28.0

24.0

 

  • Characteristic impedance Zc, Ω: 100±15

 

Operating and installation conditions:

Cables may be operated at ambient temperatures from −40 to +60°C. Cable installation is permitted at temperatures not lower than −10°C.
The minimum permissible bending radius during installation and laying shall be at least 8 times the maximum outer cable diameter.

Reliability requirements:

The minimum service life of the cables, provided that the consumer complies with the established installation rules and operating, storage and transportation conditions, shall be at least 25 years. The service life is calculated from the date of cable manufacture.

        

Construction of U/UTP Cat 5e PVC ng(A)-LS:

Conductors made of soft copper wire with polyethylene insulation are twisted into pairs with different and non-multiple lay lengths. The pairs are stranded into a core with a unidirectional lay. An outer jacket made of a halogen-free polymer compound is applied over the core, providing flame-retardant performance during group installation.

You may also be interested in:
indoor
fire-resistant
low smoke
low toxicity
LAN кабель высокочастотный парной скрутки U/UTP Cat 5e PVC нг(А)-LSLTx