High-frequency twisted pair LAN cable KSVPPet-5e (F/UTPt PE)

Manufacturing and sale of twisted pair cables KSVPPet-5e (F/UTPt PE). LAN cable delivery to all regions of Russia.

In stock: many

Delivery: from 1 business day

  • Shielded cable
  • With a UV-stabilized polyethylene sheath
  • With a self-supporting steel messenger wire
  • Sheath color: black
  • TU FKS-002-2016
Application of KSVPPet-5e (F/UTPt PE):

High-frequency twisted pair cable for structured cabling systems intended for horizontal and vertical outdoor installation along building walls, suspension on aerial communication lines, and routing between poles or buildings. The cable is designed to operate in the frequency range up to 100 MHz (Category 5 and 5e according to GOST R 54429-2011 and ISO/IEC 11801). The cables are manufactured in UHL climatic version, installation categories 1 and 2 according to GOST 15150.

Messenger wire characteristics:

Load-bearing galvanized steel messenger wire

Number and diameter of steel wires

Messenger wire diameter without sheath

Sheath thickness

Messenger wire diameter with sheath

KSVPPEt-5e 1x2

7x0.3 mm

0.9 mm

0.7 mm

2.3 mm

KSVPPEt-5e 2x2

7x0.3 mm

0.9 mm

0.7 mm

2.3 mm

KSVPPEt-5e 4x2

7x0.3 mm

0.9 mm

0.7 mm

2.3 mm

KSVPPEt-5e 10x2

7x0.5 mm

1.6 mm

0.7 mm

3.0 mm

KSVPPEt-5e 16x2

7x0.5 mm

1.6 mm

0.7 mm

3.0 mm

KSVPPEt-5e 25x2

7x0.71 mm

2.3 mm

0.7 mm

3.7 mm

 

Electrical characteristics:
  • Conductor resistance recalculated for 100 m cable length at 20 °C — not more than 9.5 Ohm;
  • DC resistance unbalance within a pair over 100 m — not more than 2%.
  • Attenuation coefficient recalculated for 100 m length at 20 °C, dB, not more than

Frequency, MHz

1

4

10

16

20

31.25

62.5

100

Attenuation, dB

2.1

4.1

6.5

8.3

9.3

11.7

17.0

22.0

 

  • Near-end crosstalk attenuation for any pair combination NEXT, recalculated for 100 m length, dB, not less than

Frequency, MHz

1

4

10

16

20

31.25

62.5

100

Attenuation, dB

65.3

56.3

50.3

47.3

45.8

42.9

38.4

35.3

 

  • Equal level far-end crosstalk attenuation for any pair combination EL FEXT, recalculated for 100 m length, dB, not less than

Frequency, MHz

1

4

10

16

20

31.25

62.5

100

Attenuation, dB

64.0

52.0

44.0

39.9

38.0

34.1

28.0

24.0

 

  • Characteristic impedance Zc, Ohm, 100±15

 

Operating and installation conditions:

The cables may be operated at ambient temperatures from −60 °C to +60 °C. Cable installation shall be performed at temperatures not lower than −20 °C.
The minimum permissible bending radius during installation and laying shall be not less than 8 maximum outer cable diameters.

Reliability requirements:

The minimum service life of the cables, provided that the established installation, operating, storage and transportation rules are observed by the consumer, shall be at least 25 years. The service life is calculated from the date of cable manufacture.

        

Construction of KSVPPet-5e (F/UTPt PE):

Symmetrical twisted pair cable with polyethylene-insulated conductors twisted into pairs with lay lengths that are neither equal nor multiples of each other. The pairs are twisted into a core with a unidirectional lay. An aluminum-polymer tape shield with a contact conductor made of tinned copper wire is applied over the core, followed by a sheath made of light- and heat-stabilized polyethylene. The cable is equipped with an external load-bearing element twisted from seven galvanized steel wires and connected to the main cable by a web, forming a figure-eight construction.